什么情況下要對空調加氟
Under what circumstances should the air conditioner be fluorinated
1、使用超過5年以上的(任何一臺分體式空調機都會自然泄漏氟立昂);
1. Used for more than 5 years (any split air conditioner will naturally leak Freon);
2、多次移機的(空調移機排空時會消耗部分氟立昂);
2. Many times of relocation (some Freon will be consumed when the air conditioner is relocated and emptied);
3、夏天外機連接點的粗管裸露處(即低壓管)不結露或不涼的;
3. In summer, the exposed part of the thick pipe (i.e. the low-pressure
pipe) at the connection point of the external machine does not condense
or cool;
4、夏天外機風扇排風不熱的;
4. In summer, the exhaust of the external fan is not hot;
5、夏天回氣壓力(粗管)低于0.4兆帕的;
5. In summer, the return gas pressure (coarse pipe) is lower than 0.4 MPa;
6、壓縮機運轉電流小于銘牌標注正常值的;
6. The operating current of the compressor is less than the normal value marked on the nameplate;
7、夏季高壓管(細管)結霜的;
7. High pressure pipe (thin pipe) frosting in summer;
8、夏季空調內機結冰或吹
泥桿 保定古箏 塑料增韌劑 拱形護坡模具 保定空調維修 托輥生產線的(有時候還伴有內機漏水);
8. Ice or fog blowing in the air conditioner in summer (sometimes accompanied by water leakage in the air conditioner);
9、冬季手摸外機銅管接口處粗管不燙手的;
9. In winter, it is not hot to touch the thick pipe at the copper pipe interface of the external machine;
10、空調有泄漏點的;
10. Air conditioners with leakage points;
11、空調開機后十幾分鐘就停機的(低壓保護或過熱保護)。
11. The air conditioner shuts down more than ten minutes after starting up (low-voltage protection or overheat protection).